The objective of this study was to evaluate the possibility of sedimentation basin omission when installed hybrid membrane filtration process in the field plant with the capacity of 500m3/day for 11 months in the "G". water purification plant in Seoul. In order to evaluate the possibility of the sedimentation basin omission, we measured the change of DOC by coagulant dosage. Dosage of PAC(power activated carbon) 4mg/L and coagulant(Al2O3 10%) 1.67mg/L were compatible to meet the water quality. Also according to the experiment without settlement process, optimization G values were determined to be 300/s, 64/s, and 32/s at the mixing tank, the first flocculator and the second flocculator, respectively. The test was performed under the conditions PAC-coagulation-no settlement-MF. As a result, a dosage of 4.0mg/L as PAC and 0.86 to 1.22mg/L as Al2O3(10%) in the condition of flux of 62.5LMH were determined to keep TMP value less than 1.0kgf/cm2.