Toluene degradation in a polyurethane biofilter at high loading

Citations

WEB OF SCIENCE

16
Citations

SCOPUS

28

초록

In the present study, toluene elimination in the polyurethane (PU) biofilter during long-term (145 day) operation was characterized, and assessed the effects of changing the inlet loading and space velocity (SV). A very high elimination capacity of 3.7 kg.M-3.h(-1) was obtained at an inlet loading of 4.0 kg.m(-3).h(-1) (inlet toluene concentration of 900 ppmv at a SV of 1,040 h(-1)). Backwashing with irrigation and compressed air allowed maintenance of a pressure drop of < 80 mm H2O.m(-1)-filter at an SV of 830 h(-1) and an elimination efficiency of > 90% during the 145 day of operation. In conclusion, the PU biofilter can overcome the problems of clogging caused by excess biomass growth and of low treatment capacities of conventional biofilters. (C) KSBB.

키워드

toluene; polyurethane; biofilter; high loading; Stenotrophomonas maltophilia; clogging; GAS-FLOW RATE; BIOLOGICAL DEODORIZATION; THIOBACILLUS-THIOOXIDANS; INLET CONCENTRATION; SCALE BIOFILTER; WASTE GASES; REMOVAL; BIOFILTRATION; VAPORS; XYLENE
제목
Toluene degradation in a polyurethane biofilter at high loading
저자
Ryu, Hee Wook; Kim, So Jong; Cho, Kyung-Suk; Lee, Tae Ho
DOI
10.1007/s12257-008-0025-4
발행일
2008-05
유형
Article
저널명
Biotechnology and Bioprocess Engineering
권
13
호
3
페이지
360 ~ 365