Purpose: This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. Methods: In 31 Sprague-Dawley rats divided into three groups (high-dose, low- dose, and control), liver fibrosis was induced by intraperitoneal administration of thioacetamide for 8 weeks. A dedicated radiographer performed SWE to measure liver stiffness in kilopascals in two sessions at a 3-day interval. We calculated correlations between liver stiffness and histopathologic results, measurement variability in each session using coefficients of variation (CoVs) and interquartile/median (IQR/M), and test-retest repeatability between both sessions using the repeatability coefficient. Results: Different levels of liver fibrosis in each group were successfully induced in the animal model. The mean liver stiffness values were 8.88 +/- 1.48 kPa in the control group, 11.62 +/- 1.70 kPa in the low-dose group, and 11.91 +/- 1.73 kPa in the high-dose group. The correlation between collagen areas and liver stiffness values was moderate (r=0.6). In all groups, the second session yielded lower CoVs (i.e., more reliable results) for liver stiffness than the first session, suggesting a training effect for the operator. The mean IQR/M values were also lower in the second session than in the first session, which had four outliers (0.21 vs. 0.12, P<0.001). The test-retest repeatability coefficient was 3.75 kPa and decreased to 2.82 kPa after removing the four outliers. Conclusion: The use of ultrasonographic SWE was confirmed to be feasible and repeatable for evaluating liver fibrosis in preclinical trials. Operator training might reduce variability in liver stiffness measurements.
키워드
- 제목
- Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
- 저자
- Shin, Youngbin; Huh, Jimi; Ham, Su Jung; Cho, Young Chul; Choi, Yoonseok; Woo, Dong-Cheol; Lee, Jeongjin; Kim, Kyung Won
- 발행일
- 2021-01
- 유형
- Article
- 저널명
- Ultrasonography
- 권
- 40
- 호
- 1
- 페이지
- 126 ~ 135
- 언어
- ENG
- 출판사
- KOREAN SOC ULTRASOUND MEDICINE
- 발행국가
- 대한민국
- 분량
- 10 페이지
- ISSN
- E 2288-5943
P 2288-5919