Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials

  • Shin, Youngbin; 
  • Huh, Jimi; 
  • Ham, Su Jung; 
  • Cho, Young Chul; 
  • Choi, Yoonseok; 
  • ... Lee, Jeongjin; 
  • 외 2명
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

Purpose: This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. Methods: In 31 Sprague-Dawley rats divided into three groups (high-dose, low- dose, and control), liver fibrosis was induced by intraperitoneal administration of thioacetamide for 8 weeks. A dedicated radiographer performed SWE to measure liver stiffness in kilopascals in two sessions at a 3-day interval. We calculated correlations between liver stiffness and histopathologic results, measurement variability in each session using coefficients of variation (CoVs) and interquartile/median (IQR/M), and test-retest repeatability between both sessions using the repeatability coefficient. Results: Different levels of liver fibrosis in each group were successfully induced in the animal model. The mean liver stiffness values were 8.88 +/- 1.48 kPa in the control group, 11.62 +/- 1.70 kPa in the low-dose group, and 11.91 +/- 1.73 kPa in the high-dose group. The correlation between collagen areas and liver stiffness values was moderate (r=0.6). In all groups, the second session yielded lower CoVs (i.e., more reliable results) for liver stiffness than the first session, suggesting a training effect for the operator. The mean IQR/M values were also lower in the second session than in the first session, which had four outliers (0.21 vs. 0.12, P<0.001). The test-retest repeatability coefficient was 3.75 kPa and decreased to 2.82 kPa after removing the four outliers. Conclusion: The use of ultrasonographic SWE was confirmed to be feasible and repeatable for evaluating liver fibrosis in preclinical trials. Operator training might reduce variability in liver stiffness measurements.

키워드

Shear wave elastography; Ultrasound; Liver fibrosis; Liver stiffness; Repeatability; ACOUSTIC RADIATION FORCE; HEPATIC-FIBROSIS; IMAGING BIOMARKERS; STIFFNESS; VARIABILITY; RELIABILITY; PERFORMANCE
제목
Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
저자
Shin, Youngbin; Huh, Jimi; Ham, Su Jung; Cho, Young Chul; Choi, Yoonseok; Woo, Dong-Cheol; Lee, Jeongjin; Kim, Kyung Won
DOI
10.14366/usg.19088
발행일
2021-01
유형
Article
저널명
Ultrasonography
권
40
호
1
페이지
126 ~ 135