표준화된 인체모델을 이용한 공진형 무선전력전송 시스템의 효율 변화 및 인체 안전성 분석

Efficiency and EMF Safety Analysis of Wireless Power Transfer System Using Standard Human Model

초록

In this paper, resonant wireless power transfer systems are designed with double loop resonant coils for the resonant frequency of 150kHz. The transfer efficiency characteristics is analyzed according to the coil size, and the distance and misalignment between the coils. Then the change in efficiency is investigated when a human model is located between the resonant coils using the homogeneous human phantom of IEC-62311 standard. Also, in order to assess the safety of the wireless power transfer system, the induced current density inside the human model is calculated when it is exposed to the magnetic field of a plane wave and resonant coil. Then, the results are compared with the exposure limits in the EMF (electromagnetic field) safety guidelines.

키워드

Wireless Power Transfer; Efficiency; Human Body Safety
제목
표준화된 인체모델을 이용한 공진형 무선전력전송 시스템의 효율 변화 및 인체 안전성 분석
제목 (타언어)
Efficiency and EMF Safety Analysis of Wireless Power Transfer System Using Standard Human Model
저자
신한수; 변진규
발행일
2013-11
저널명
조명.전기설비학회논문지
권
27
호
11
페이지
96 ~ 103