Frequency domain indirect identification of AMB rotor systems based on fictitious proportional feedback gain

Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

It is very difficult to directly identify an unstable system with uncertain dynamics from frequency domain input-output data. Hence, in these cases, closed-loop frequency responses calculated using a fictitious feedback could be more identifiable than open-loop data. This paper presents a frequency domain indirect identification of AMB rotor systems based on a Fictitious proportional feedback gain (FPFG). The closed-loop effect due to the FPFG can enhance the detectability of the system by moving the system poles, and significantly weigh the target mode in the frequency domain. The effectiveness of the proposed identification method was verified through the frequency domain identification of active magnetic bearing rotor systems.

키워드

Frequency domain identification; Indirect identification; System with rigid modes; AMB rotor system; ACTIVE MAGNETIC BEARING; DESIGN; STABILITY; ACTUATOR
제목
Frequency domain indirect identification of AMB rotor systems based on fictitious proportional feedback gain
저자
Ahn, Hyeong-Joon; Kim, Chan-Jung
DOI
10.1007/s12206-016-1106-5
발행일
2016-12
유형
Article
저널명
Journal of Mechanical Science and Technology
권
30
호
12
페이지
5389 ~ 5395