상세 보기
광펄스 살균을 위한 다채널 고전압 컨버터의 개발
- 이영우;
- 김형원;
- 최우진
초록
As the demand for the fresh non-thermal food is increased, it is required to develop the fast and perfect sterilization method. The conventional sterilization method using ultraviolet lamp has some disadvantages such as imperfect sterilization and longer process time. In this research, IPL(Intense Pulsed Light) sterilization system is introduced to overcome the drawbacks of the conventional system, and suitable power supply architecture for the system is discussed. Since the IPL sterilization system uses Zenon lamps which requires the 600∼2,100[V] for the lightning and 16∼30[kV] for the trigger, the converter for the system should be able to generate the high voltage and to discharge the large amount of energy instantaneously. In this research a new power system architecture which has a modified forward converter topology with two switches for generating high voltage and a capacitor bank to control the energy for the lightning by switching is introduced.
키워드
- 제목
- 광펄스 살균을 위한 다채널 고전압 컨버터의 개발
- 제목 (타언어)
- Development of the High Voltage Converter for the Pulsed Light Sterilization
- 저자
- 이영우; 김형원; 최우진
- 발행일
- 2012-06
- 저널명
- 조명.전기설비학회논문지
- 권
- 26
- 호
- 6
- 페이지
- 29 ~ 37
- 언어
- KOR
- 출판사
- 한국조명.전기설비학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- P 1229-4691