Protective Coordination of the OCR with the Voltage Component in a Closed-Loop Power Distribution System with the FCL

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

1

초록

Recently, the requirement of the electrical energy from the renewable source has been growing in the South Korea since government’s energy plan to generate the electrical power of 20% as renewable source. In addition, these renewable power plants have been constructed on not only the existing power plant’s side but also customer’s side. These changes in power distribution system cause the fault current to increase higher and to reverse the direction of the fault current. Variable countermeasures to reduce the fault current have been studied and the introduction of the superconducting fault current limiter (SFCL) in the power distribution system, one of them, has been actively reported. However, the installation of the SFCL can affect the power system protection because of the fault current’s decrease or increase, which depends on the construction of the power distribution system. Especially, the application of the SFCL in a closed-loop power distribution system can cause the delayed trip operation or the fast trip operation of the over-current relay (OCR), one of the representative protective devices widely used in a power distribution system. This change can influence on the existed protective coordination. In this paper, the OCR with voltage component, one of the methods to suppress its trip operation’s change in a power distribution system with a closed loop construction due to the application of the SFCL, was suggested and the protection coordination between the OCRs in a power distribution system with a closed loop was analyzed. It was confirmed that a simple using voltage component in the OCR could cause the trip variation of the reverse direction OCR in loop power system and it can be improved by matching the relaying voltage components. © 2020, The Korean Institute of Electrical Engineers.

키워드

Overcurrent relay (OCR)Power system protectionProtection coordinationSuperconducting fault current limiter (SFCL)Energy policyFault current limitersPower plantsSuperconducting fault current limitersSurge protectionElectrical energyOvercurrent relaysPower distribution systemPower system protectionProtection coordinationProtective coordinationsProtective devicesSuperconducting faultcurrent limiters (SFCL)Electric power system protection
제목
Protective Coordination of the OCR with the Voltage Component in a Closed-Loop Power Distribution System with the FCL
저자
Lim, Seung-taekLim, Sung-hun
DOI
10.1007/s42835-020-00522-6
발행일
2020-11
유형
Article
저널명
Journal of Electrical Engineering & Technology
15
6
페이지
2451 ~ 2457