Unintentional arc faults due to damaged power line cords and loose connections can cause serious fires; thus, they are a safety hazard in residential areas. Therefore, arc fault circuit interrupters are being increasingly used in homes to protect against arcs that may cause fires. In this paper, we analyzed the ignition characteristics of series arcs on the basis of load current. Furthermore, we recommended suitable arc clearing times through characteristics analysis in the Korean residential electric environment. We determined the arc clearing time via the carbonized path arc clearing time test using an ultraviolet signal detecting system according to the test method of the UL 1699 standard. In the experiments, heat-resistant indoor PVC insulated (HIV) wires, which is a type of residential electrical wire, were used as the wire specimens.
키워드
- 제목
- Ignition Characteristics of Residential Series Arc Faults in 220-V HIV Wires
- 저자
- Moon, Won-Sik; Kim, Jae-Chul; Jo, Ara; Bang, Sun-Bae; Koh, Won-Sik
- 발행일
- 2015-05
- 유형
- Article
- 권
- 51
- 호
- 3
- 페이지
- 2054 ~ 2059
- 출판사
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
- 발행국가
- 미국
- 분량
- 6 페이지
- ISSN
- E 1939-9367
P 0093-9994