초록
In order to determine the extent to which explosion-proof devices should be used in case of leakage in industrial sites handling flammable gases and flammable liquids, the calculation for classification of hazardous area should be carried out. At this time, the Korean Industrial Standard KS C 60079-10-1 citing IEC 60079-10-1, which is an international standard applied, is widely used. However, since the proposed liquid release rate equation does not clearly suggest a method of calculating the amount of vaporized, the calculation process is complicated, or excessive or insufficient results are induced. In order to improve this point, we propose an optimal liquid release rate calculation method, simplify the calculation process, and propose a practical and reasonable method.
키워드
- 제목
- 폭발위험장소 설정 시 인화성액체 누출률의 최적 산정방법 연구
- 제목 (타언어)
- A Study on the Optimum Estimation of Flammable Liquid Release Rate for the Classification of Hazardous Area
- 저자
- 유원종; 김병직; 이준원; 조규선; 박교식
- 발행일
- 2020-12
- 저널명
- 한국위험물학회지
- 권
- 8
- 호
- 2
- 페이지
- 9 ~ 18