비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼

Column filled with Fe-GAC and GAC to remove both As(V) and Fe(III)

초록

First of all, Fe or/and Mn immobilized granular activated carbons (Fe-GAC, Mn-GAC, (Fe, Mn)-GAC) were synthesized and tested to remove arsenate (As(V)). The results in batch test indicated that Fe-GAC removed As(V) effectively, even though the surface area of Fe-GAC was reduced largely. Moreover, adsorption isotherm test indicated that the experimental data fit well with Langmuir model and the maximum adsorption capacity (qmax) of Fe-GAC for As(V) was 3.49 mg g-1, which was higher than GAC (2.24 mg g-1). In column test, the simulated water, which consisted of As(V), Fe(III), Mn(II) and Ca(II) in tap water, was used. Fe-GAC column with 1 hr of pre-washing time treated As(V) effectively while GAC column removed Fe(III) better than Fe-GAC column. Moreover, the increasing pre-washing time from 1 to 9 hour in Fe-GAC column enhanced Fe(III) removal with little negative impact of As(V) removal. Mostly, the column filled with Fe-GAC and GAC (i.e. the mass ratio of Fe-GAC:GAC = 2:8) showed the higher treatability of both As(V) and Fe(III), even it operated with 1 hr pre-washing time.

키워드

흡착비소철고정활성탄Fe-GACAdsorptionArsenateFe-GACFe-GAC + GAC columnIron
제목
비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼
제목 (타언어)
Column filled with Fe-GAC and GAC to remove both As(V) and Fe(III)
저자
이용수도시현홍성호
발행일
2016-02
저널명
상하수도학회지
30
1
페이지
87 ~ 97